HELLO I HAVE A DOUBT, IT COMES SOME ELBOW FOR DISCHARGE OF TOILET BUT THAT HAS ANOTHER INPUT BEHIND 110
since then I have to connect the entrance of the pipe that comes from the floor above,

2 Proposed Solutions

http://www.industriassaladillo.com.ar/downloads/Awaduct.pdf: no, the name is not horizontal, and the entrances are 63, use a single MH branch at 45 ° with 45 ° elbows when assembling the pipe avoids the maximum changes of direction remember to vent the pipe in the bathroom above greetings
  • 29 days ago

    Avatar de polo666535

    Uhhhhhhh I didn't know about the ventilation, the plemoro didn't do any of that to me, look that the toilets are only independent of the rest of the waters, and then go to a septic chamber, then I'm going to ventilate him.

SOLUTION ACCEPTED
Hi. Elbows like the ones you mention if I'm not mistaken don't come. What you can implement is a Y branch of Ø 110 mm at 45º and a 45º elbow for the entrance of the PB toilet and in the free mouth connect the pipe that comes from PA. Another option is to place this branch lying down and rush with the spout up to the side entrance. Regards