Good night, I am reviewing a MIDAS brand split of 3000 fgr that works approximately 7 and the compressor only turns off, then tries to start and the thermal protector does not leave it, I measured the amperage and cut it in 4 amp. What can be the causes of not starting ?. Thank you


1 Proposed Solution

SOLUTION ACCEPTED
Hi Gusteler, yes a compressor of that capacity, triggers the thermal protection with only 4 amps of consumption, obviously that the thermal protection itself must be fatigued or devalued, because a protection for that type of compressor, should support an average consumption of between 5.5 and 6.2 amps. Luck. S @ lu2 friovega63.